Description

I. Product Overview

The 3351/1151GP pressure transmitter is used to measure the liquid level, density and pressure of liquid, gas or steam, and then converted to 4 to 20mA DC signal output. The ZY-3351/1151GP intelligent pressure transmitter can communicate with the HART handset, set up, monitor or build the scene monitoring system with the upper computer.
The 3351/1151GP on-site adjustment intelligent pressure transmitter is a new product developed by our company according to the requirements of the field. It can be separated from the manual operator and realize the zero adjustment and configuration operation by pressing the buttons.
Two. Performance specification
(zero reference range, under the reference conditions, silicone oil filled, 316 L stainless steel isolation diaphragm).

1.1. reference accuracy
1.1.1. digital and intelligence: + 0.1% calibration range
1.1.2. analog, linear: + 0.2% calibration range
1.2. stability
1.2.1. number and intelligence: 6 months, + 0.1%URL
1.2.2. simulation, linear: 6 months, + 0.2%URL
1.3. ambient temperature effect
1.3.1. digital and intelligence:
Zero error: + 0.2%URL/56 C
Total error: + (0.2%URL+0.18% check range) /56 C
1.3.2. simulation and linearity
Zero error: + 0.5%URL/56 C
Total error: + (0.5%URL+0.5% check range) /56 C
1.4. vibration effect
Under any axial direction, the effect of 200Hz vibration is + 0.05%URL/g.
1.5. power influence
Less than + 0.005% output range / volt.
1.6. load effect:
There is no load effect unless the supply voltage changes.
1.7. electromagnetic interference / radio frequency interference (EMI/RFI effect)
From 20 to 1000MHz, when the field reaches 30V/M, the output drift is less than 0.1%.


1.8. installation position influence
Zero drift is at most + 0.25kPa. All zero drift
It can be corrected; it has no effect on the range.
2. functional specifications
2.1. measurement range: 0-0.125-41370KPa
2.2. zero and range
2.2.1. figures, intelligence
It can be adjusted by the local range and zero button or remotely adjusted with the HART hand-held device.
2.2.2. simulation and linearity
Continuous and adjustable range and zero point
2.3. zero positive and negative transfer
When the zero point moves negatively, the lower limit of the range must be greater than or equal to -URL. When the zero point is moving forward, the upper limit of the measuring range must be less than or equal to +URL. The calibration range must be greater than or equal to a small range.
2.4. output
Number and intelligence:
4 ~ 20mA DC, users can choose linear or square root output. The digital process variables are superimposed on the 4 ~ 20mA signal and can be used by the upper computer using the HART protocol.
Simulation and linearity:
4 ~ 20mA DC, linearly with the process pressure.
2.5. explosion-proof rating
EXdIICT6

Three. Product selection mode

3351/1151GP

Pressure transmitter


Code

Range KPa

Two

0-0.125 ~ 1.5

Three

0-1.3 ~ 7.5

Four

0-6.2 ~ 37.4

Five

0-31.1 ~ 186.8

Six

0-117 to 690

Seven

0-345 to 2068

Eight

0-1170 to 6890

Nine

0-3450 to 20680

Zero

0-6890 to 41370


Code

output

E

4-20mA

S

Intelligent type


Code name

Structural materials

Flanges and joints

Exhaust / drain valve

Isolation diaphragm

Filling liquid

Twenty-two

316 stainless steel

316 stainless steel

316 stainless steel

silicone oil

Twenty-three

316 stainless steel

316 stainless steel

Hastelloy C

Twenty-four

316 stainless steel

316 stainless steel

Monel

Twenty-five

316 stainless steel

316 stainless steel

tantalum

Thirty-three

Hastelloy C

Hastelloy C

Hastelloy C

Thirty-five

Hastelloy C

Hastelloy C

tantalum

Forty-four

Monel

Monel

Monel


Code name

option

M1

0-100% linear indicator

M2

LED display table

M3

LCD display table

B1

Pipe bent bracket

B2

Plate bent bracket

B3

Pipe mounting bracket

D1

The side relief valve is on the upper part of the pressure chamber.

D2

The side relief valve is under the pressure chamber.

No note

1/2NPT taper pipe thread joint

C2

T-shaped threaded joint M20 * 1.5, ball conical connector with rear welded 14 lead pressure pipe.

D

Flameproof EXd II BT4 EXdIICT6

I

Intrinsically safe ia II CT4