I. Product Overview
The WSSX series explosion-proof electrical contact metal bimetallic thermometer shell is made of aluminum alloy. Through the aluminum alloy shell, the circuit of sparking and arcing in the instrument can be separated from the explosive gas mixture outside the watch case, so as to achieve the purpose of flameproof.
The performance of the bimetallic thermometer of the explosion-proof electrical contact is in line with the 1 part of the BG3836.1-2000 explosion-proof electrical equipment for explosive atmospheres: General requirements and the second part of the GB3836.2-2000 explosion-proof electrical equipment for explosive atmospheres: the standard of flameproof electrical equipment "d".
The bimetallic thermometer of the explosion-proof electrical contact has an electrical contact device, that is, a mechanical electrical contact. When the temperature of the tested medium changes, the thin shaft and the steering gear of the free end drive the pointer and the moving contact to rotate. The temperature change value is indicated on the scale plate. When it contacts or disconnects with the fixed contact point (upper and lower limit contacts), the relay and contactor in the circuit system are moved to achieve the purpose of automatic control and alarm.
The WSSX series explosion-proof electrical contact bimetallic thermometer is a single needle indicating thermometer, which is fixed by one end of a bimetallic strip twisted around a spiral tube and connected with a pointer by a free end and rotated with the change of temperature, and drives the pointer to rotate to indicate the temperature. It is the temperature measurement of liquid, steam and gas medium and solid surface in the range of -80 to +500 C in the process of petroleum, coking, chemical, pharmaceutical and other enterprises.
Two. Main technical parameters
Scale nominal diameter: 100
Thermal response time: less than 40s
Flameproof level: DIIBT4
Rated power: 10VA
Zui high working voltage: 220V
* high working current: 0.7A
Three. Selection of bimetal thermometers for explosion-proof electrical contacts:
WSS | Bimetallic thermometer | ||||||
X | Electrical contacts | ||||||
-4 | Dial diameter 100 | ||||||
Dial form | Zero | axial | |||||
One | radial | ||||||
Eight | universal | ||||||
Install fixed form | Zero | No fixed device | |||||
One | Movable external thread | ||||||
Two | Movable internal thread | ||||||
Three | Fixed thread | ||||||
Four | Fixed flange | ||||||
Five | Sleeve thread | ||||||
Six | Clamp flange | ||||||
Flameproof | B | Flameproof level ExdiiBT4 | |||||
Contact protection form | M | Upper and lower limit (not specified) | |||||
N | Double ceiling | ||||||
P | Double lower limit |
Selection parameters: after selecting the above models, the temperature range of the thermometer should be provided (the recommended range of calibration range * the maximum value is 1.5~2 times of normal service temperature), the depth of penetration, the diameter of probe rod, the material of probe rod, and the working pressure of the measured medium.
Four. Measuring temperature range
Model | Temperature range C | Accuracy grade | Protective tube material | Specifications | Installation device |
WSSX-410B | -80-+40 -40-+80 0-50 0-100 0-150 0-200 0-300 0-400 0-500 | One point five | 1Cr18NI9Ti Three hundred and four Three hundred and sixteen 316L Haste C-276 H.AIIoyc-276 | Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand | Thread without fixtures |
WSSX-480B | |||||
WSSX-411B | Movable external thread | ||||
WSSX-481B | |||||
WSSX-412B | Movable internal thread | ||||
WSSX-482B | |||||
WSSX-413B | Fixed flange | ||||
WSSX-483B | |||||
WSSX-414B | Fixed thread | ||||
WSSX-484B | |||||
WSSX-415B | Sleeve thread | ||||
WSSX-485B | |||||
WSSX-416B | Clamp flange | ||||
WSSX-486B |