Remote bimetal thermometer (with thermal resistor / couple)
Description
I. application
The bimetallic thermometer and thermocouple / thermal resistor are integrated to meet the needs of field temperature measurement and long distance transmission. It can directly measure the temperature of liquid, vapor and gas medium and solid surface in the range of -80-+500 C in various production processes.
Two, main technical parameters
1. The nominal diameter of the dial is 60, 100 and 150.
2, thermal response time: less than 40s
3. Accuracy: 1, 1.5
Thermocouple: I grade 1.5 C; II 2.5 C.
Thermal resistance: Class A + (0.15+0.005ItI)
B grade (0.30+0.005)
4, protection level: IP55
Three. Type and specification
Type number | Grading number | Temperature range C | Accuracy grade | Protective tube material | Insertion length |
WSSE-401 | E | -80-+40 -40-+80 0-50 0-100 0-150 0-200 0-300 0-400 0-500 | One point five | 1Cr18Ni9Ti
Three hundred and four
Three hundred and sixteen
316L
Haste C-276 | One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand |
WSSE-501 | |||||
WSSE-411 | |||||
WSSE-511 | |||||
WSSE-481 | |||||
WSSE-581 | |||||
WSSP-401 | Pt100 | ||||
WSSP-501 | |||||
WSSP-411 | |||||
WSSP-511 | |||||
WSSP-481 | |||||
WSSP-581 | |||||
WSSXE-401 | E | ||||
WSSXP-401 | Pt100 | ||||
WSSXE-411 | E | ||||
WSSXP-411 | Pt100 | ||||
WSSXE-481 | E | ||||
WSSXP-481 | Pt100 |
Selection notes
1) model
2) thermocouple (resistance) indexing number
3) accuracy of thermocouple (resistance)
4) accuracy of bimetal thermometer
5) temperature range
6) installation and fixation
7) protective tube material
8) length or insertion depth
For example: thermocouple thermocouple with double metal, axial type, E type, I level, temperature range 0-400 degrees, movable thread M27*2, protection tube 316, insert length 300mm.
WSSE-401, 0-400 C, L=300mm, I, protection tube 316, thread M27*2