Flame retardant sheath control cable
1, usage: This product is used for electrical appl
Description
Product Description: |
1, usage: This product is used for electrical appliances and instrument wiring in the distribution equipment with AC rated voltage 500V or DC voltage 1000V or below. 2, product usage characteristics: the long-term allowable working temperature of cable conductor should not exceed 70 C. The temperature of the cable should not be less than 0 C when laid, and the bending radius should not be less than 10 times of the outer diameter of the cable. Cables with armoured or copper tape shields shall not be less than 12 times the diameter of the cables. 3, product standard: GB9330.2-88 "PVC insulation and sheath control cable" 4, cable type, name and scope of use. |
Model | Name | Scope of use |
ZR-KVV | Flame retardant PVC insulation, flame-retardant PVC sheathed control cable | It is laid in indoor, cable trench, pipeline and underground. |
ZR-KVVP | Flame retardant PVC insulation, flame retardant PVC sheathed copper wire braided shielding control cable | It has anti-interference capability in indoor, cable trench, pipeline and underground. |
ZR-KVVP | Flame retardant PVC insulation, flame-retardant PVC sheathed soft control cable | Laying indoors and moving to soft places. |
ZR-KVVRP | Flame retardant PVC insulation, flame retardant PVC sheathed copper wire braid shielded soft control cable | Ditto has anti-interference capability. |
ZR-KVVP2 | Flame retardant PVC insulation, flame-retardant PVC sheathed copper tape wrapped shielding control cable | Ditto. |
ZR-KVV22 | Flame-retardant PVC insulation, flame-retardant PVC sheathed steel tape armored control wire | It can be used in indoor, cable trench, pipeline and underground, and can bear larger mechanical external force. |
ZR-KVV32 | Flame retardant PVC insulation, fine steel wire armoured flame-retardant PVC sheathed control cable | It can be used in indoor, cable trench, pipeline, shaft and underground, and it can bear certain pulling force. |
Note: flame retardancy (ZR) and halogen free flame retardant (ZRA) control cables can be produced according to user needs.
5. Scope of production
Model | Rated voltage (V) | Nominal cross section of conductor (mm2) | |||||||
Zero point five | Zero point seven five | One | One point five | Two point five | Four | Six | Ten | ||
Core number | |||||||||
ZR-KVV ZR-KVVP | 450/750 | - | 2-61 | 2-14 | 2-10 | ||||
ZR-KVVP2 | - | 4-61 | 4-14 | 4-10 | |||||
ZR-KVV22 | - | 7-61 | 4-61 | 4-14 | 4-10 | ||||
ZR-KVV32 | - | 19-61 | 7-61 | 4-14 | 4-10 | ||||
ZR-KVVR | 4-46 | - | - | ||||||
ZR-KVVRP | 4-61 | 4-48 | 4-4 |