1492851016041.jpg

Platinum rhodium thermocouple

The WR series platinum rhodium thermocouple is als
Description

I. Product Overview
The WR series platinum rhodium thermocouple is also called the precious metal thermocouple. As a temperature measuring sensor, it is commonly used in conjunction with temperature transmitters, regulators and display instruments. It is composed of a process control system to directly measure or control the temperature of liquids, vapors and gas medium and solid surfaces in the production range of 0-1800 degrees.
The platinum rhodium thermocouple is made up of two different conductors at the ends of the conductor. When the temperature of the two junction points is different, the thermal current will be generated in the loop. If there is a temperature difference between the working end and the reference end of the thermocouple, the display instrument will indicate the temperature corresponding to the thermoelectric potential generated by the thermocouple.
The thermoelectric heat of the platinum rhodium thermocouple will increase with the increase of the temperature of the measuring terminal. Its size is only related to the temperature of the thermocouple material and the two ends, and has nothing to do with the length and diameter of the thermoelectric pole.
The shapes of various platinum rhodium thermocouples are often very different because of their needs, but their basic structures are basically the same. They are usually made up of main components such as thermal electrodes, insulation sleeve protection tubes and junction boxes.



Two. Product application
Platinum rhodium thermocouple is suitable for high temperature applications in various production processes. It is widely used in powder metallurgy, sintering bright furnace, vacuum furnace, smelting furnace, glass, steelmaking furnace and ceramic and industrial salt bath furnace.
Three. Main technical parameters
Electrical outlet: M20x1.5, NPT1/2
Accuracy: I, II
Protection level: IP65
Diameter of filament: 0.5
Nominal pressure: atmospheric pressure
Four. Measurement temperature and tolerance

Thermocouple category
Code name
Graduation
temperature
Measuring temperature
Allowable deviation of T C
Platinum rhodium 30- platinum rhodium 6
WRR
B
0~1800
0-1600
+ 1.5 or + 0.25%t
Platinum rhodium 10- platinum
WRP
S
0~1600
0-1300
+ 1.5 or + 0.25%t
Nickel chromium nickel silicon
WRN
K
0~1300
0-1100
+ 2.5 or + 0.75%t
Nickel chromium copper nickel
WRE
E
0~800
0-800
+ 2.5 or + 0.75%t

Five. Models and specifications

 

Model
Graduation
Temperature range C

Protective tube material

Thermal response time

Specifications
D
L x L

WRP-130
WRP2-130

S
0-1300
High alumina
< 150S
Phi 16

300x150
350x200
400x250
450x300
550x400
650X500
900x750
1150x1000
1650x1500 2150x2000

WRP-131
WRP2-131

< 360S
Phi 25

WRQ-130
WRQ2-130

R
0-1300
< 150S
Phi 16

WRQ-131
WRQ2-131

< 360S
Phi 25

WRR-130
WRR2-130

B
0-1600
Corundum tube
< 150S
Phi 16

WRR-131
WRR2-131

< 360S
Phi 25

1) thermocouple I order;

2) the non implanted part is carbon steel.

Products include: single platinum rhodium thermocouple; double platinum rhodium thermocouple; armoured platinum rhodium thermocouple; high temperature platinum rhodium thermocouple;


Browse:
Return To The Top

分享到: